{"id":3489,"date":"2026-06-16T12:26:21","date_gmt":"2026-06-16T10:26:21","guid":{"rendered":"https:\/\/www.rocketronics.de\/en\/?page_id=3489"},"modified":"2026-06-16T12:26:33","modified_gmt":"2026-06-16T10:26:33","slug":"jmc-wiring-commissioning","status":"publish","type":"page","link":"https:\/\/www.rocketronics.de\/en\/products\/jmc\/jmc-wiring-commissioning\/","title":{"rendered":"Connecting JMC Motors \u2013 Power Supply, Wiring &#038; Commissioning"},"content":{"rendered":"<!-- ============================================================\r\n     PAGE 6 \u2014 \/en\/products\/jmc\/jmc-wiring-commissioning\/\r\n     Title: Connecting JMC Motors \u2013 Power Supply, Wiring & Commissioning\r\n     Slug: jmc-wiring-commissioning\r\n     Meta description:\r\n       Connect JMC motors correctly: size the power supply, wire step\/dir,\r\n       charge capacitor, RS232 parameterisation and commissioning \u2013\r\n       explained in a practical way.\r\n     ============================================================ -->\r\n\r\n<div class=\"jmc-page\">\r\n\r\n  <section class=\"jmc-hero\">\r\n    <h1>Connecting &amp; Commissioning JMC Motors<\/h1>\r\n    <p class=\"jmc-lead\">JMC motors with integrated driver are quickly wired: they only need a supply voltage and a control signal. This page summarises the most important points on power supply, wiring and first commissioning.<\/p>\r\n  <\/section>\r\n\r\n  <section>\r\n    <h2>1. Supply Voltage &amp; Power Supply<\/h2>\r\n    <p>Each motor has a nominal voltage (24 \/ 36 \/ 48 \/ 72 V depending on frame size). Use a power supply that delivers this voltage. For milling machines, the power supply should be able to provide briefly about 2\/3 of the combined current of all motors; since the axes never all run at full load simultaneously, this works out very well.<\/p>\r\n    <h3>Charge Capacitor Against Voltage Spikes<\/h3>\r\n    <p>Decelerating servo motors feed energy back, which can briefly raise the supply voltage. A DIN-rail charge capacitor module buffers these spikes and protects the power supply and motor electronics. We offer three types: 4700 \u00b5F \/ 63 V, 9400 \u00b5F \/ 63 V and 9400 \u00b5F \/ 80 V. For power supplies with higher continuous current, a 9400 \u00b5F module is recommended; make sure the voltage rating (63 V or 80 V) is above your supply voltage. All models can be found under <a href=\"https:\/\/www.rocketronics.de\/shop\/en\/power-supplies\/capacitors\/\">charge capacitors in the shop<\/a>.<\/p>\r\n  <\/section>\r\n\r\n  <section>\r\n    <h2>2. Control Signal: Step\/Dir or Pulse<\/h2>\r\n    <p>The motors are controlled via step\/dir signals from your CNC controller \u2013 compatible for example with Estlcam terminal adapters, Eding CNC, CSMIO and many other controllers. The signal inputs for DIR, PUL and ENA are built with optocouplers and accept a signal voltage of 3.3 V to 24 V. At signal voltages above 5 V, a suitable series resistor must be connected in series to limit the input current of the optocoupler. For clean, fast signal transmission to several motors, we offer matching RJ45 adapter sets that considerably simplify the wiring.<\/p>\r\n  <\/section>\r\n\r\n  <section>\r\n    <h2>3. Parameterisation via RS232 (optional)<\/h2>\r\n    <p>Many JMC motors can be fine-tuned via an RS232 interface (e.g. current, microstep resolution, control behaviour). For this you need a USB-RS232 converter and the matching RS232 cable. As delivered, the motors are already sensibly preconfigured and usually run without further adjustment.<\/p>\r\n    <figure class=\"jmc-figure jmc-figure-inline\"><img decoding=\"async\" src=\"https:\/\/www.rocketronics.de\/shop\/images\/product_images\/popup_images\/HL-340.webp\" alt=\"USB-RS232 converter HL-340 for parameterising JMC motors\" loading=\"lazy\"><figcaption>USB-RS232 converter HL-340 \u2013 for the optional fine-tuning of the motor parameters.<\/figcaption><\/figure>\r\n  <\/section>\r\n\r\n  <section>\r\n    <h2>4. First Commissioning \u2013 Checklist<\/h2>\r\n    <p>Proceed in a structured way for the first commissioning: check supply voltage and polarity, wire the step\/dir signal correctly, first test the motor without load and at low speed, check direction of rotation and homing, then gradually increase acceleration and speed. Make sure the connectors are firmly seated \u2013 the matching PCB connectors in various pin counts can be found in the <a href=\"https:\/\/www.rocketronics.de\/en\/products\/jmc\/jmc-accessories\/\">accessories<\/a>.<\/p>\r\n    <div class=\"jmc-warn\">\r\n      <p class=\"jmc-warn-title\">\u26a0 Safety notes for commissioning<\/p>\r\n      <p>During first commissioning, incorrect settings can cause unexpected and forceful movements. Therefore note:<\/p>\r\n      <ul>\r\n        <li><strong>First tests without load and at reduced speed.<\/strong> If possible, disconnect the motor from the mechanics or operate with a large safety distance until direction of rotation and behaviour are confirmed.<\/li>\r\n        <li><strong>Increase acceleration and maximum speed gradually.<\/strong> Values that are too high can lead to step losses, jerky movements or a &#8220;runaway&#8221; drive that moves the axis uncontrollably.<\/li>\r\n        <li><strong>Set up and test limit and reference switches before the first move.<\/strong> They are the last safeguard against overrunning the travel limits and against collisions.<\/li>\r\n        <li><strong>Keep the emergency stop within reach.<\/strong> Make sure the system can be de-energised immediately at any time, and never reach into the travel range while the motors are active.<\/li>\r\n        <li><strong>Wrong direction of rotation or swapped axes<\/strong> can cause movements in the wrong direction \u2013 check each axis individually.<\/li>\r\n        <li><strong>Electrical safety:<\/strong> only change the wiring when de-energised. Charged capacitors can still carry voltage after switch-off.<\/li>\r\n      <\/ul>\r\n    <\/div>\r\n    <figure class=\"jmc-figure jmc-figure-inline\"><img decoding=\"async\" src=\"https:\/\/www.rocketronics.de\/shop\/images\/product_images\/popup_images\/jmc-10-pol.webp\" alt=\"Pluggable PCB connector 10-pin for JMC motors\" loading=\"lazy\"><figcaption>Matching pluggable PCB connectors make a clean connection easier.<\/figcaption><\/figure>\r\n  <\/section>\r\n\r\n\r\n  <section>\r\n    <h2>The Most Important Connection Signals in Detail<\/h2>\r\n    <p>Regardless of frame size, all JMC motors work with the same set of control signals. The pulse signal (PUL\/Step) sets the steps or the target position, the direction signal (DIR) determines the direction of rotation. The enable signal (ENA) switches the motor inactive: if an active ENA signal is present, the power stage is switched off and the shaft can rotate freely. If the signal is absent, the motor is activated and holds its position. This logic can be inverted via the parameters if needed. The alarm output (ALM) is designed as an open-collector output and becomes active as soon as a fault condition occurs \u2013 for example on blockage, overcurrent, over-temperature or excessive position deviation. This allows the controller to detect the fault and stop the machine in a controlled manner.<\/p>\r\n    <h3>Reverse-Polarity Protection on iHSSC Models<\/h3>\r\n    <p>The closed-loop models with the type designation iHSSC have additional reverse-polarity protection on the supply voltage. If the power supply is accidentally connected with reversed polarity, this circuit protects the electronics from damage \u2013 a practical safety plus, especially during initial commissioning and in service cases.<\/p>\r\n  <\/section>\r\n\r\n  <section class=\"jmc-cta\">\r\n    <h2>Matching Accessories for Commissioning<\/h2>\r\n    <p>Power supplies, capacitors, adapters, connectors and cables \u2013 all from stock.<\/p>\r\n    <p><a class=\"jmc-btn jmc-btn-primary\" href=\"https:\/\/www.rocketronics.de\/en\/products\/jmc\/jmc-accessories\/\">To the JMC accessories<\/a><\/p>\r\n  <\/section>\r\n\r\n<\/div>\r\n\r\n<script type=\"application\/ld+json\">\r\n{\r\n  \"@context\":\"https:\/\/schema.org\",\r\n  \"@type\":\"BreadcrumbList\",\r\n  \"itemListElement\":[\r\n    {\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/www.rocketronics.de\/en\/els\/\"},\r\n    {\"@type\":\"ListItem\",\"position\":2,\"name\":\"JMC Motors\",\"item\":\"https:\/\/www.rocketronics.de\/en\/products\/jmc\/jmc-motors\/\"},\r\n    {\"@type\":\"ListItem\",\"position\":3,\"name\":\"Wiring & Commissioning\",\"item\":\"https:\/\/www.rocketronics.de\/en\/products\/jmc\/jmc-wiring-commissioning\/\"}\r\n  ]\r\n}\r\n<\/script>\r\n\r\n<style>\r\n.jmc-figure{margin:1.2em 0;text-align:center}\r\n.jmc-figure img{max-width:100%;height:auto;border-radius:8px;border:1px solid #e0e6ee}\r\n.jmc-figure-inline img{max-width:300px}\r\n.jmc-figure figcaption{font-size:.85rem;color:#667;margin-top:.5em;line-height:1.5}\r\n.jmc-warn{background:#fff8ec;border:1px solid #e8c98a;border-left:4px solid #d9971f;border-radius:6px;padding:1em 1.2em;margin:1.4em 0}\r\n.jmc-warn-title{font-weight:700;color:#9a6a12;margin:0 0 .5em}\r\n.jmc-warn ul{margin:.4em 0 0;padding-left:1.3em}\r\n.jmc-warn li{margin:.4em 0;line-height:1.55}\r\n<\/style>","protected":false},"excerpt":{"rendered":"Connecting &amp; Commissioning JMC Motors JMC motors with integrated driver are quickly wired: they only need a supply voltage and a control signal. This page summarises the most important points on power supply, wiring and first commissioning. 1. Supply Voltage &amp; Power Supply Each motor has a nominal voltage (24 \/ 36 \/ 48 \/&hellip;","protected":false},"author":1,"featured_media":0,"parent":3470,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"class_list":["post-3489","page","type-page","status-publish","hentry","no-wpautop","description-off"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.8 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Connecting JMC Motors \u2013 Power Supply, Wiring &amp; Commissioning - Rocketronics English<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.rocketronics.de\/en\/products\/jmc\/jmc-wiring-commissioning\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Connecting JMC Motors \u2013 Power Supply, Wiring &amp; Commissioning - Rocketronics English\" \/>\n<meta property=\"og:description\" content=\"Connecting &amp; Commissioning JMC Motors JMC motors with integrated driver are quickly wired: they only need a supply voltage and a control signal. This page summarises the most important points on power supply, wiring and first commissioning. 1. Supply Voltage &amp; Power Supply Each motor has a nominal voltage (24 \/ 36 \/ 48 \/&hellip;\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.rocketronics.de\/en\/products\/jmc\/jmc-wiring-commissioning\/\" \/>\n<meta property=\"og:site_name\" content=\"Rocketronics English\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/rocketronics\/\" \/>\n<meta property=\"article:modified_time\" content=\"2026-06-16T10:26:33+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.rocketronics.de\/shop\/images\/product_images\/popup_images\/HL-340.webp\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"4 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.rocketronics.de\\\/en\\\/products\\\/jmc\\\/jmc-wiring-commissioning\\\/\",\"url\":\"https:\\\/\\\/www.rocketronics.de\\\/en\\\/products\\\/jmc\\\/jmc-wiring-commissioning\\\/\",\"name\":\"Connecting JMC Motors \u2013 Power Supply, Wiring & Commissioning - Rocketronics English\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.rocketronics.de\\\/en\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.rocketronics.de\\\/en\\\/products\\\/jmc\\\/jmc-wiring-commissioning\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.rocketronics.de\\\/en\\\/products\\\/jmc\\\/jmc-wiring-commissioning\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.rocketronics.de\\\/shop\\\/images\\\/product_images\\\/popup_images\\\/HL-340.webp\",\"datePublished\":\"2026-06-16T10:26:21+00:00\",\"dateModified\":\"2026-06-16T10:26:33+00:00\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.rocketronics.de\\\/en\\\/products\\\/jmc\\\/jmc-wiring-commissioning\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.rocketronics.de\\\/en\\\/products\\\/jmc\\\/jmc-wiring-commissioning\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.rocketronics.de\\\/en\\\/products\\\/jmc\\\/jmc-wiring-commissioning\\\/#primaryimage\",\"url\":\"https:\\\/\\\/www.rocketronics.de\\\/shop\\\/images\\\/product_images\\\/popup_images\\\/HL-340.webp\",\"contentUrl\":\"https:\\\/\\\/www.rocketronics.de\\\/shop\\\/images\\\/product_images\\\/popup_images\\\/HL-340.webp\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.rocketronics.de\\\/en\\\/products\\\/jmc\\\/jmc-wiring-commissioning\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Startseite\",\"item\":\"https:\\\/\\\/www.rocketronics.de\\\/en\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Produkte\",\"item\":\"https:\\\/\\\/www.rocketronics.de\\\/en\\\/products\\\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"JMC Motors\",\"item\":\"https:\\\/\\\/www.rocketronics.de\\\/en\\\/products\\\/jmc\\\/\"},{\"@type\":\"ListItem\",\"position\":4,\"name\":\"Connecting JMC Motors \u2013 Power Supply, Wiring &#038; Commissioning\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.rocketronics.de\\\/en\\\/#website\",\"url\":\"https:\\\/\\\/www.rocketronics.de\\\/en\\\/\",\"name\":\"Rocketronics English\",\"description\":\"Electronics and more\",\"publisher\":{\"@id\":\"https:\\\/\\\/www.rocketronics.de\\\/en\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.rocketronics.de\\\/en\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/www.rocketronics.de\\\/en\\\/#organization\",\"name\":\"Rocketronics\",\"url\":\"https:\\\/\\\/www.rocketronics.de\\\/en\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.rocketronics.de\\\/en\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/www.rocketronics.de\\\/en\\\/wp-content\\\/uploads\\\/sites\\\/3\\\/2019\\\/07\\\/raketenlogo_retina_logo_360.png\",\"contentUrl\":\"https:\\\/\\\/www.rocketronics.de\\\/en\\\/wp-content\\\/uploads\\\/sites\\\/3\\\/2019\\\/07\\\/raketenlogo_retina_logo_360.png\",\"width\":360,\"height\":53,\"caption\":\"Rocketronics\"},\"image\":{\"@id\":\"https:\\\/\\\/www.rocketronics.de\\\/en\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.facebook.com\\\/rocketronics\\\/\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Connecting JMC Motors \u2013 Power Supply, Wiring & Commissioning - Rocketronics English","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.rocketronics.de\/en\/products\/jmc\/jmc-wiring-commissioning\/","og_locale":"en_US","og_type":"article","og_title":"Connecting JMC Motors \u2013 Power Supply, Wiring & Commissioning - Rocketronics English","og_description":"Connecting &amp; Commissioning JMC Motors JMC motors with integrated driver are quickly wired: they only need a supply voltage and a control signal. This page summarises the most important points on power supply, wiring and first commissioning. 1. Supply Voltage &amp; Power Supply Each motor has a nominal voltage (24 \/ 36 \/ 48 \/&hellip;","og_url":"https:\/\/www.rocketronics.de\/en\/products\/jmc\/jmc-wiring-commissioning\/","og_site_name":"Rocketronics English","article_publisher":"https:\/\/www.facebook.com\/rocketronics\/","article_modified_time":"2026-06-16T10:26:33+00:00","og_image":[{"url":"https:\/\/www.rocketronics.de\/shop\/images\/product_images\/popup_images\/HL-340.webp","type":"","width":"","height":""}],"twitter_card":"summary_large_image","twitter_misc":{"Est. reading time":"4 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.rocketronics.de\/en\/products\/jmc\/jmc-wiring-commissioning\/","url":"https:\/\/www.rocketronics.de\/en\/products\/jmc\/jmc-wiring-commissioning\/","name":"Connecting JMC Motors \u2013 Power Supply, Wiring & Commissioning - Rocketronics English","isPartOf":{"@id":"https:\/\/www.rocketronics.de\/en\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.rocketronics.de\/en\/products\/jmc\/jmc-wiring-commissioning\/#primaryimage"},"image":{"@id":"https:\/\/www.rocketronics.de\/en\/products\/jmc\/jmc-wiring-commissioning\/#primaryimage"},"thumbnailUrl":"https:\/\/www.rocketronics.de\/shop\/images\/product_images\/popup_images\/HL-340.webp","datePublished":"2026-06-16T10:26:21+00:00","dateModified":"2026-06-16T10:26:33+00:00","breadcrumb":{"@id":"https:\/\/www.rocketronics.de\/en\/products\/jmc\/jmc-wiring-commissioning\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.rocketronics.de\/en\/products\/jmc\/jmc-wiring-commissioning\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.rocketronics.de\/en\/products\/jmc\/jmc-wiring-commissioning\/#primaryimage","url":"https:\/\/www.rocketronics.de\/shop\/images\/product_images\/popup_images\/HL-340.webp","contentUrl":"https:\/\/www.rocketronics.de\/shop\/images\/product_images\/popup_images\/HL-340.webp"},{"@type":"BreadcrumbList","@id":"https:\/\/www.rocketronics.de\/en\/products\/jmc\/jmc-wiring-commissioning\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Startseite","item":"https:\/\/www.rocketronics.de\/en\/"},{"@type":"ListItem","position":2,"name":"Produkte","item":"https:\/\/www.rocketronics.de\/en\/products\/"},{"@type":"ListItem","position":3,"name":"JMC Motors","item":"https:\/\/www.rocketronics.de\/en\/products\/jmc\/"},{"@type":"ListItem","position":4,"name":"Connecting JMC Motors \u2013 Power Supply, Wiring &#038; Commissioning"}]},{"@type":"WebSite","@id":"https:\/\/www.rocketronics.de\/en\/#website","url":"https:\/\/www.rocketronics.de\/en\/","name":"Rocketronics English","description":"Electronics and more","publisher":{"@id":"https:\/\/www.rocketronics.de\/en\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.rocketronics.de\/en\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/www.rocketronics.de\/en\/#organization","name":"Rocketronics","url":"https:\/\/www.rocketronics.de\/en\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.rocketronics.de\/en\/#\/schema\/logo\/image\/","url":"https:\/\/www.rocketronics.de\/en\/wp-content\/uploads\/sites\/3\/2019\/07\/raketenlogo_retina_logo_360.png","contentUrl":"https:\/\/www.rocketronics.de\/en\/wp-content\/uploads\/sites\/3\/2019\/07\/raketenlogo_retina_logo_360.png","width":360,"height":53,"caption":"Rocketronics"},"image":{"@id":"https:\/\/www.rocketronics.de\/en\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/rocketronics\/"]}]}},"_links":{"self":[{"href":"https:\/\/www.rocketronics.de\/en\/wp-json\/wp\/v2\/pages\/3489","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.rocketronics.de\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.rocketronics.de\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.rocketronics.de\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.rocketronics.de\/en\/wp-json\/wp\/v2\/comments?post=3489"}],"version-history":[{"count":1,"href":"https:\/\/www.rocketronics.de\/en\/wp-json\/wp\/v2\/pages\/3489\/revisions"}],"predecessor-version":[{"id":3490,"href":"https:\/\/www.rocketronics.de\/en\/wp-json\/wp\/v2\/pages\/3489\/revisions\/3490"}],"up":[{"embeddable":true,"href":"https:\/\/www.rocketronics.de\/en\/wp-json\/wp\/v2\/pages\/3470"}],"wp:attachment":[{"href":"https:\/\/www.rocketronics.de\/en\/wp-json\/wp\/v2\/media?parent=3489"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}